NetPing 2 IP PDU ETH R2

Remote Power Control Unit Over Ethernet (IP PDU) for 2 sockets C13.

  • 2 independently controlled “computer” power sockets C13 (100V .. 250V);
  • a plastic compact case;
  • an ability to connect external sensors: temperature, humidity, leakage, door metal sensor, power supply, and others;
  • Ethernet port 10/100-BASE-TX;
  • an operating temperature range: -30°C .. +50°C (non-condensing, normal air humidity);
  • optionally: a built-in ionistor for sending notifications when the main power is turned off.

Description

Name Status Price, $
NetPing 2 IP PDU ETH R2 ACTIVE 141

General usage conditions - for industrial and commercial usage in conditions of high humidity (0-95%, non-condensing). The device is not intended for domestic use.

NetPing 2 IP PDU ETH R2 is related to the class of devices IP PDU (IP power distribution unit). These devices allow you to turn on, turn off and restart the equipment remotely (via the device’s web interface, using SNMP commands or the HTTP API) by controlling 100 .. 250 V 50/60 Hz sockets. An important feature of NetPing 2 IP PDU ETH R2 is a port for connecting an external battery pack, which will allow the device to function and send information about monitoring events if there is no main power supply.

NetPing 2 IP PDU ETH R2 is usually used for:

  • Remote power management inside ATMs, vending machines, payment terminals and other similar equipment (a modification with a GSM modem). At the same time, this device can monitor the internal operating conditions of the equipment (for example, it can control an operating temperature of a bill acceptor, so that it does not exceed the permissible range), signal problems both via the Ethernet network and using SMS commands. If there is no power from an external power supply, the device will remain connected via SMS messages and carry on monitoring the condition of sensors.
  • Restarting freezing modems, access points, routers, servers and other computer equipment without the need to be physically there. If a network is not available, an operation can be performed via an SMS command. This saves the effort and expense of many trips to turn on/off this frozen device.
  • Remote turning on/ off additional computer equipment. The physical turning-on of backup servers, routers, access points can be done as needed in a manual or automatic mode and turned off when you do not need them anymore. This saves energy and reduces wear and tear on equipment that is needed only occasionally or at certain intervals.
  • Remote turning on/off conference call monitors, monitors in a game club or an Internet cafe. Monitors can be controlled both via the Ethernet/Internet network and via SMS commands.
  • Remote control of air conditioners, ventilation systems and microclimate maintenance systems. Connected sensors allow you to monitor any current situation, and remote control of 220 V sockets allows you to turn on the required system without being physically present at the facility, including in an automatic mode.

Device Capabilities

Be notified

  • Information about the status of sensors is available through the web interface
  • Email notifications
  • Email notifications about events
  • SNMP v1 trap
  • SYSLOG notifications

Use web interface from any device

  • configuration
  • sensor monitoring
  • notification and alarm
  • scheduler
  • watchdog
  • NTP-time
  • firmware update
  • event log

Power up with remote control and automation

  • Web interface
  • URL-encoded commands
  • SNMP v1 control
  • LOGIC rules
  • Scheduler for connected devices
  • Watchdog over ICMP to react on changed conditions

Enterprise-level reliability

  • External battery support for uninterrupted operation
  • Nonvolatile log file
  • Internal supercapacitor to keep notifications flow up to 6 minutes when all other power sources are lost
  • Designed and built for uninterruptible operation in 24/7 unattended mode

Support & Warranty

  • 3 years from production date
  • Lifetime professional support
 

Features Included

Remote management of device sockets via the Ethernet/Internet network

Each output socket of NetPing rack power distribution unit can be remotely switched on/switched off/reloaded. Sockets can be managed through a built-in web interface, with the help of any browser or using SNMP commands.

Switching on/off sockets on a schedule

NetPing rack power distribution unit can switch on and off a voltage on its built-in sockets on its own on a weekly schedule, switch on/off a voltage several times a day, use a special schedule for holidays. This may be useful for a daily/weekly forced reboot of external devices or for turning off unused equipment in a certain time of a day.

A watchdog for automatic reloading of an external equipment

If any external device, a router or an access point freezes sometimes, NetPing rack power distribution unit can automatically reload these devices. To do this, it constantly inquires indicated IP addresses by the ping protocol. If it gets no response, it will automatically reload a connected device by turning off and turning on its power supply.

 

Specification

Solution

The device is intended for indoor use only

indoor only

External sensors can be connected:

temperature, humidity, door, leakage, supply voltage and other

Length of the sensor loop to the device

no more than 50 meter

Form factor and mounting requirement

a plastic compact case, standalone unit

Static IP

Yes + Mac address

Device control interface

web-interface

Ability to connect the battery module

Yes

Fanless solution

Yes

Functionalities

Main functionalities

Number of independent power channels managed remotely

2 independently controlled “computer” power sockets C13 (100V .. 250V)

Number of power sources

1

Short protect circuit

Internal self-healing fuse

Summary output power

1500 W

Watchdog function

Yes

Managing sockets on a schedule

Yes

Individual socket output power

1500 W

Extra functionalities

Remote monitoring of temperature

up to 8 pcs T811 sensors

Airflow sensors

up to 4 pcs sensors

Door sensors

up to 4 pcs sensors

Leakage sensors

up to 4 pcs sensors

Motion sensors

up to 3 pcs sensors

Buzzer

1 buzzer

Input-Output lines

4

1-wire sensors support

No

Managed NetPing AC/DIN socket

up to 4 pcs sockets

Voltage (electric power) presence by external sensors NetPing Supply Voltage Sensor 995S2

Yes, up to 4 pcs sensors

Email notifications

Yes

Get time from NTP

Yes

Internal log

Yes

Configuring logic rules

Yes

SNMP control

Yes, SNMP v1

SNMP trap

Yes, SNMP v1

Syslog support

Yes

URL-encoded commands

Yes

Hardware specification

Connectors

Ethernet port

1 x 10/100 BASE-TX

IO (input-output) lines for connecting external sensors and controlling external devices

4

Control and display

Power LED indicator

Yes

Reset button

Yes

Power supply and parameters

Electric power (main Input)

100 … 250V 50/60 Hz

Power plug

Euro plug, detachable power cord 1.8 meter

Power consumption, by a unit itself

7.5 W

Dimensions and logistics parameters

Water proof case

No

Device dimensions (W x D x H)

145 x 78 x 57 mm

Package box dimensions (W x D x H)

255 x 93 x 82 mm

Net weight

334 g

Unit packaged weight (transportation weight)

 

Device packing containment

NetPing 2 IP PDU ETH 53R14 (device), rubber pads, zip package, power cable, screwdriver, box

Operating conditions

Ambient air temperature for operation

-30°С … +50°С

Relative humidity

5…95 % (relative humidity has to be not more than 80% while the ambient air temperature is 25°С exact, non-condensing)

Operating atmospheric pressure range

84,0 … 106,7 kPa

Storage conditions

Ambient air temperature for storage

-40°С … +70°С

Storage Relative Humidity

5…95 %

Device reliability

Mean time between failures, MTBF

27 000 h

Estimated life expactancy of the product

At least 3 years

Limited manufacturer’s warranty

3 years from production date

Lifetime technical support

Yes

Documentation and files

Manuals

Firmware

Certificates

Additional technical files

How to Buy?

You can purchase all equipment offered at our website for USD directly from us NetPing east Co Ltd. company or from our official partners. All prices indicated on our website are current ones.

To purchase NetPing devices, email please your request to sales@netpingdevice.com. In the email, indicate please the next:

  • Name and number of models of devices that you want to purchase. Do not forget to indicate sensors and accessories that are necessary for you.
  • Company name and a name of the recipient of the parcel with equipment.
  • Complete mailing address for equipment delivery.
  • Contacts (e-mail and a phone number).

Afterwards, a sales manager will prepare and send you an invoice in USD to pay the order (the details of our bank account and PayPal account are specified on the invoice). The invoice is valid for 10 days, and if you do not pay it within the specified time frame, the invoice will be canceled. To renew the order, you will need to send a repeat request to a sales manager.

Equipment can be sold for 100% prepayment only!

We make discounts to retail customers. Provided by lot (lot - one time buying/shipment):

  • Lot total amount > 600 USD → 5% discount.
  • Lot total amount > 1500 USD → 10% discount.
  • Lot total amount > 3000 USD → special discount.

We deliver equipment to any country of the world for free. Free delivery of devices without batteries is provided by EMS company. Free delivery of devices with batteries is provided by DHL company.

Customers from Russian Federation are welcome to visit our Russian website www.netping.ru and choose there a more convenient method to purchase our goods.

Compatible devices