NetPing 4 IP PDU ETH R8

Power management and monitoring device over Ethernet for 10″/19″ racks (Switched Monitored IP PDU). 4 Schuko controlled sockets.

  • switched load power: 3.5 kW, total for all sockets. Up to 1.5 kW per socket;
  • metal case for installation in a 19′/10′ 1U rack or for mounting on a flat surface;
  • support for external 1-wire sensors (temperature, humidity, power quality);
  • 6 input/output lines for connecting external dry contact sensors and actuators;
  • 2 x 10/100-BASE-TX Ethernet ports;
  • power consumption monitoring meters on each socket.

Description

Name Status Price, $
NetPing 4 IP PDU ETH R8 NEW 247

General usage conditions - for industrial and commercial usage in conditions of high humidity (0-95%, non-condensing). The device is not intended for domestic use.

NetPing 4 IP PDU R8 is a device of power supply sockets remote management via Ethernet/Internet network. This power distribution unit allows remote turning on, turning off and restarting the equipment by managing 100V … 240V AC, 50/60 Hz sockets, as well as to measure the active power consumption for each outlet.

Modifications

Name

SMS notifications and management

Sockets

Power consumption monitoring meters on each socket

NetPing 4 IP PDU GSM3G R9

3G GSM modem

IEC320-C13

NetPing 4 IP PDU GSM3G R8

 3G GSM modem

“Schuko”, Type F

NetPing 4 IP PDU ETH R8

“Schuko”, Type F

Applicable solutions:

  • Remote control of power supply inside ATMs, vending machines, payment terminals and other similar equipment. At the same time, the device can monitor the internal operating conditions of the equipment (for example, ensure that the operating temperature of the bill acceptor does not exceed the permissible range) and signal problems via the Ethernet network.
  • Reload modems, access points, switches, routers, servers and other computer equipment that freezes with no need to access it physically. 
  • Remote turning on/turning off additional computer equipment. This allows to save electricity and reduce equipment wear out, because its work is required sometimes or in certain periods of time.
  • Notifications about power failure at a remote site.
  • Remotely turn on and off conference call monitors, monitors in a gaming club or internet cafe. Monitors can be controlled via Ethernet/Internet.
  • Remote monitoring of power consumption.
  • Remote management of air conditioners, ventilation systems and climate control systems. Connected sensors allow current situation surveillance, and a remote 100V … 240V AC, 50/60 Hz sockets management allows turning on a necessary system with no physical presence on an object, including automatic mode.

Device Capabilities

Be notified

  • Information about the status of sensors is available through the web interface
  • Email notifications
  • Email notifications about events
  • SNMP v2 trap
  • SYSLOG notifications

Use web interface from any device

  • configuration
  • sensor monitoring
  • notification and alarm
  • scheduler
  • watchdog
  • NTP-time
  • firmware update
  • event log

Power up with remote control and automation

  • Web interface
  • URL-encoded commands
  • SNMP v1 control
  • LOGIC rules
  • Scheduler for connected devices
  • Watchdog over ICMP to react on changed conditions

Enterprise-level reliability

  • External battery support for uninterrupted operation
  • Nonvolatile log file
  • Internal supercapacitor to keep notifications flow up to 6 minutes when all other power sources are lost
  • Designed and built for uninterruptible operation in 24/7 unattended mode

Support & Warranty

  • 3 years from production date
  • Lifetime professional support
 

Features Included

Remote management of device sockets via the Ethernet/Internet network

Each output socket of NetPing rack power distribution unit can be remotely switched on/switched off/reloaded. Sockets can be managed through a built-in web interface, with the help of any browser or using SNMP commands.

Switching on/off sockets on a schedule

NetPing rack power distribution unit can switch on and off a voltage on its built-in sockets on its own on a weekly schedule, switch on/off a voltage several times a day, use a special schedule for holidays. This may be useful for a daily/weekly forced reboot of external devices or for turning off unused equipment in a certain time of a day.

A watchdog for automatic reloading of an external equipment

If any external device, a router or an access point freezes sometimes, NetPing rack power distribution unit can automatically reload these devices. To do this, it constantly inquires indicated IP addresses by the ping protocol. If it gets no response, it will automatically reload a connected device by turning off and turning on its power supply.

 

Specification

Solution

The device is intended for indoor use only

indoor only

A built-in 3G GSM modem for SMS management and notification

No

Length of the sensor loop to the device

no more than 50 meter

Form factor and mounting requirement

a metal case for installing into a 10′ rack 1U or mounting on a flat surface

Housed in robust case

made of metal

Static IP

Yes + Mac address

Device control interface

web-interface

Built-in ionistor for the operation of the warning system in the absence of 220 V

No

Ability to connect the battery module

Yes

Fanless solution

Yes

Functionalities 

Main functionalities

Number of independent power channels managed remotely

4 controllable 100V … 240V AC, 50/60 Hz sockets (IEC320-C13)

Number of power sources

1

Short protect circuit

Internal self-healing fuse

Summary output power

3500 W

Watchdog function

Yes

Managing sockets on a schedule

Yes

Individual socket output power

1500 W

Extra functionalities

Remote monitoring of temperature

up to 8 pcs 1-wire (THS) sensors

Remote monitoring of relevant ambient humidity

up to 4 pc 1-wire (HS) sensors

Airflow sensors

up to 6 pcs sensors

Door sensors

up to 6 pcs sensors

Leakage sensors

up to 6 pcs sensors

Motion sensors

up to 6 pcs sensors

Buzzer

6 buzzer

Sensors status information transmission via SNMP protocol

intergations with Zabbix, PRTG Network Monitor, OpenNMS, Nagios, Cacti, The Dude, Monit, and similar monitoring systems

Input-Output lines

6

1-wire sensors support

Yes

Managed NetPing AC/DIN socket

up to 6 pcs sockets

Voltage (electric power) presence and voltage quality monitoring by external sensors NetPing Supply Voltage Sensor 995S2 and NetPing Power Quality Monitoring Sensor 1-wire 910S21

Yes, up to 6 pcs sensors

Built-in web server

Yes

LOGIC support

Yes

Sending notification when the power supply is cut off

Yes

Email notifications

Yes

Get time from NTP

Yes

Internal log

Yes

Configuring logic rules

Yes

SNMP control

Yes, SNMP v1

SNMP trap

Yes, SNMP v1

Syslog support

Yes

URL-encoded commands

Yes

Hardware specification 

Connectors

Ethernet port

2 x 10/100 BASE-TX

IO (input-output) lines for connecting external sensors and controlling external devices

6

Control and display

Power LED indicator

Yes

Reset button

Yes

Power supply and parameters

Electric power (main Input)

100 … 250V 50/60 Hz

Power plug

Euro plug, detachable power cord 1.8 meter

Power consumption, by a unit itself

12 W

Dimensions and logistics parameters 

Water proof case

No

Device dimensions (W x D x H)

218 x 180 x 44 mm

Package box dimensions (W x D x H)

499 x 253 x 63 mm

Net weight

1000 g

Unit packaged weight (transportation weight)

1300 g

Device packing containment

NetPing 4 IP PDU GSM3G R8 (device), terminals, a power cable, a screwdriver, a user guide, box

Operating conditions 

Outdoor / indoor usage restriction

For indoor use only

Ambient air temperature for operation

-30°С … +50°С

Relative humidity

5…95 % (relative humidity has to be not more than 80% while the ambient air temperature is 25°С exact, non-condensing)

Operating atmospheric pressure range

84,0 … 106,7 kPa

Storage conditions

Ambient air temperature for storage

-40°С … +70°С

Storage Relative Humidity

5…95 %

Device reliability

Mean time between failures, MTBF (controllers)

27 000 h

Estimated life expactancy of the product

At least 3 years

Limited manufacturer’s warranty

3 years from production date

Lifetime technical support

Yes

Documentation and files

How to Buy?

You can purchase all equipment offered at our website for USD directly from us NetPing east Co Ltd. company or from our official partners. All prices indicated on our website are current ones.

To purchase NetPing devices, email please your request to sales@netpingdevice.com. In the email, indicate please the next:

  • Name and number of models of devices that you want to purchase. Do not forget to indicate sensors and accessories that are necessary for you.
  • Company name and a name of the recipient of the parcel with equipment.
  • Complete mailing address for equipment delivery.
  • Contacts (e-mail and a phone number).

Afterwards, a sales manager will prepare and send you an invoice in USD to pay the order (the details of our bank account and PayPal account are specified on the invoice). The invoice is valid for 10 days, and if you do not pay it within the specified time frame, the invoice will be canceled. To renew the order, you will need to send a repeat request to a sales manager.

Equipment can be sold for 100% prepayment only!

We make discounts to retail customers. Provided by lot (lot - one time buying/shipment):

  • Lot total amount > 600 USD → 5% discount.
  • Lot total amount > 1500 USD → 10% discount.
  • Lot total amount > 3000 USD → special discount.

We deliver equipment to any country of the world for free. Free delivery of devices without batteries is provided by EMS company. Free delivery of devices with batteries is provided by DHL company.

Customers from Russian Federation are welcome to visit our Russian website www.netping.ru and choose there a more convenient method to purchase our goods.

Compatible devices